Sale!
, ,

Chiller Water Cooling JL-6000SS Chiller, adjustable to a minimum of 5 degrees + Stainless 304 cover

Original price was: ฿67,200.Current price is: ฿42,000.

There are products.

Chiller Chiller Water Cooling

Chiller Water Cooling JL-6000SS

Chiller, adjustable to a minimum of 5 degrees + Stainless 304 cover

Cooling system, cooling system, chiller / industrial water chiller, water chiller for factory

Precise Temperature Control Industrial Cooling System

 

  • Thailand is located in a tropical area. The weather is hot all year round. In the use of machinery, electronic equipment and other devices in industrial plants, when the temperature increases, the inside of the machine will overheat, resulting in equipment damage, inefficient operation and if the heat accumulates more and more, it may cause a fire. The heat in the machine is like the heat in a person's body. When our body temperature is higher than normal, we will get sick and will not be able to do things efficiently. Therefore, we take into account the maintenance of the machine and can solve the problem of high temperature machines by: Chiller Be a helper
  • Thailand is located in the tropical zone. It is hot all year round. In machine operation Electronic device and other industrial equipment when there is an increase in temperature causing the inside of the machine to overheat resulting in malfunctioning equipment not working efficiently and find more and more heat equations there may be a fire. Machine heat Is like the heat of a person's body, when the body temperature increases beyond normal we will get sick and unable to do things at their full potential Therefore, we consider the maintenance of the machine. And can solve problems with high temperature machines with Chiller to help.

  • Chiller It is a cooling machine, a water chiller, both large and small. Its main function is to produce coolness, reduce the temperature and dissipate heat by using water as the main factor in exchanging and transferring coolness from the chiller. Currently, chillers are used in industrial plants to cool machines, maintain machines to last longer and help maintain the efficiency of the machines.
  • Chiller  is a refrigeration. Water cooler There are both large and small. It is the main function of cold production reduce the temperature and cooling.

  • Use water as the main medium for exchanging and dissipating heat from the cooling machine.
  • Chillers are currently used in industrial plants to cool down machines, maintain them for a long time, and help maintain their efficiency.
  • For example, closed-loop wells, hydraulic injection molding machines, and CNC machines.
  • For example : Closed system pond, Hydraulic injection molding machine, CNC Engraving Cutting CO2, CNC Laser Engraving UV, CNC Router Milling, CNC Fiber Laser and other.

Chiller Water Cooling JL-5000SS

Chiller, adjustable to a minimum of 5 degrees + Stainless 304 cover

Used for cooling CNC fiber laser machines. Easy to use, makes the CNC fiber laser machines not hot while working.

– Custom-made chiller model can adjust the temperature to a minimum of 5 degrees.
– The structure (Cover) is made of Stainless 304, strong, durable and rust-free.

FEATURES

  1. JL – 5000/5200 refrigerating capacity up to 1750 w.
  2. Through cold coal solenoid valve control, real-time adjust the volume of cold, guarantee the stability and accuracy of cooling system.
  3. An intelligent and constant two kinds of working mode, suitable for all kinds of environmental temperature.
  4. Temperature overtemperature alarm sensor fault self-diagnosis function.
  5. Has the compressor through the load protection, water flow alarm function.

 

Machine Dimension

Machine Components

Technical Parameters

 

Download the Chiller JL-5000/5200 user manual.  Click here

 

Chiller temperature adjustment procedure from CW/JL5000/5200 and above

 

Compare Chiller-5000 with Chiller-5200

 


Compare all models of water chillers

Chiller Water Cooling Model JL

 


Working between CO2 Laser Tube and Chiller

 


Additional options: Heat Exchanger

Heat Exchanger  Connect to the Chiller and immerse in water to further reduce the water temperature.

The price is only 3,000 baht!!

 

Installation of Heat Exchanger with chiller

Heat Exchanger Accessories for chillers to further reduce water temperature | SALECNC.net

 


Chiller Water Cooling VS Cooling Tower

Cooling Tower Used in industry Hydraulic Injection Molding Machine Mostly because cooling towers have quite a few disadvantages. The machine is large, it is an open system that is difficult to maintain, dust and sediment are easily able to enter the machine, which negatively affects the operation and shortens the lifespan.

Therefore, the manufacturing industry tends to turn to use Chiller (Chiller Water Cooling) The machine is small, compact, saves working space, is a closed system, prevents dust and sediment well, and has a long service life.

 

Cooling Tower Chiller Water Cooling
❌ Open system

❌ Open system operation

✅ Closed system

✅ Closed-system operation

❌ Since the machine is an open system Causing dust and other sediments to enter the machine easily. It will clog, rust and affect the usability of the machine.

❌ Since it works as an open system, dust, debris, etc. are very likely to enter the machine, causing blockage, rust, and definitely affecting the machine's operation.

✅ The machine is a closed system. Prevents dust and other debris from entering the machine. Changing the water is easy.

✅ With a closed system operation, it prevents dust and sediment from entering the machine. Changing water is also convenient.

❌ Cleaning made difficult.

❌ Cleaning the machine is difficult.

✅ Cleaning made easy.

✅ Cleaning the machine is easy.

❌ The machine is large, takes up quite a lot of work space.

❌ The machine is large and requires a lot of working space.

✅ The machine is small, save working space.

✅ The machine is small in size, saving a lot of working space.

❌ Short term

❌ Short lifespan

✅ Long term

✅ Long service life

❌ Cheap… but not worth it !

❌ Cheap but not worth the maintenance, repair and short lifespan, wasting budget in the future.

✅ Expensive… but worth it

✅ More expensive but worth it, easy to maintain and helps reduce costs well.

 

If interested or have questions, call
061-509-6388 (Chompoo)
098-997-4199 (Fern)
02-312-0227 (office)
E-mail : Sales@salecnc.com

  LINE SCAN:


รูปภาพของปุ่มลิงค์ไปยัง LINE ของ Sale CNC Add Line: @123wotsb Fern (sales engineer) '
รูปภาพของปุ่มลิงค์ไปยัง LINE ของ Sale CNC Add Line: @sales Chompoo (sales engineer)

 

Technical parameters

Chiller Water Cooling – Model JL

Chiller JL – All

Model JL-3000 JL-5000 JL-5200 JL-6000
Voltage 220V
Current 0.35A 0.35-2.8A 1.3-7A
Frequency 50Hz
Compressor Power (±3%) 485W 980W
Rafrigeration Capacity (±3%) 50W/C 1.36KW 1.75KW 3.05KW
British Thermal Unit 4,640BTU/Hr 5,971BTU/Hr 10,406BTU/Hr
Ton of Refrigeration 0.3Ton 0.4Ton 0.8Ton
Pump Voltage/Power 24VDC/35W 24VDC/55W 220V/250W
Max.lift 10M 15M 28M
Max.flow 11L/min , 0.66m3/h 19L/min , 1.14m3/h 30L/min , 1.8m3/h
Inlet and outlet External Ø12mm brabed connector External Ø12mm brabed connector , Ø8/10/12mm speedy connector 40mm Inner teeth
Machine Dimension 485*390*265mm 560*470*285mm 580*460*820mm
Package Dimension 570*350*470mm 650*380*540mm
NW 9.8KG 23KG 24KG 45KG
GW 12KG 25KG 26KG

 

Chiller JL-3000

Model JL-3000
Voltage 220V
Current 0.35A
Frequency 50Hz
Compressor Power (±3%) 50W/C
Pump Voltage/Power 24VDC/35W
Max.lift 10M
Max.flow 11L/min , 0.66m3/h
Inlet and outlet External Ø12mm brabed connector
Machine Dimension 485*390*265mm
Package Dimension 570*350*470mm
NW 9.8KG
GW 12KG

 

Limitation of Chiller JL-3000

Model JL/CW-3000 From model JL/CW-5000 up
Compressor Don't have Have
Temperature control Can't control the temperature Temperature control
Reduction of temperature The unit will adjust the temperature to the normal temperature. For example, the normal temperature is 32 degrees. The machine will adjust the temperature down to 32 degrees Can adjust the temperature The machine will work only when the temperature drops to the set temperature

 

Chiller JL-3000 VS Chiller JL-5000

Model JL-3000 JL-5000
Voltage 220V
Current 0.35A 0.35-2.8A
Frequency 50Hz
Compressor Power (±3%) 50W/C 485W
Rafrigeration Capacity (±3%) 1.36KW
British Thermal Unit 4,640BTU/Hr
Ton of Refrigeration 0.3Ton
Pump Voltage/Power 24VDC/35W 24VDC/55W
Max.lift 10M
Max.flow 11L/min , 0.66m3/h
Inlet and outlet External Ø12mm brabed connector External Ø12mm brabed connector , Ø8/10/12mm speedy connector
Machine Dimension 485*390*265mm 560*470*285mm
Package Dimension 570*350*470mm 650*380*540mm
NW 9.8KG 23KG
GW 12KG 25KG

 

Chiller JL-5000/5200

Model JL-5000 JL-5200
Voltage 220V
Current 0.35-2.8A
Frequency 50Hz
Compressor Power (±3%) 485W
Rafrigeration Capacity (±3%) 1.36KW 1.75KW
British Thermal Unit 4,640BTU/Hr 5,971BTU/Hr
Ton of Refrigeration 0.3Ton 0.4Ton
Pump Voltage/Power 24VDC/55W
Max.lift 10M 15M
Max.flow 11L/min , 0.66m3/h 19L/min , 1.14m3/h
Inlet and outlet External Ø12mm brabed connector , Ø8/10/12mm speedy connector
Machine Dimension 560*470*285mm
Package Dimension 650*380*540mm
NW 23KG 24KG
GW 25KG 26KG

 

Chiller JL-6000

Model JL-6000
Voltage 220V
Current 1.3-7A
Frequency 50Hz
Compressor Power (±3%) 980W
Rafrigeration Capacity (±3%) 3.05KW
British Thermal Unit 10,406BTU/Hr
Ton of Refrigeration 0.8Ton
Pump Voltage/Power 220V/250W
Max.lift 28M
Max.flow 30L/min , 1.8m3/h
Inlet and outlet 40mm Inner teeth
Machine Dimension 580*460*820mm
NW 45KG

 


Chiller Water Cooling – Model JLFL

Chiller JLFL – All

Model JLFL-1000 JLFL-1500 JLFL-2000 JLFL-3000 JLFL-4000 JLFL-6000
Voltage 220V 220V/380V 380V
Current 9.8A 13.5A 15A 11.5A 12.5A 15.5A
Frequency 50Hz
Input Power 2.35KW 2.625KW 2.825KW 4.29KW 4.68KW 5.85KW
Rafrigeration Capacity (±3%) 4.25KW 5.52KW 7.5KW 8.2KW 9.5KW 15KW
British Thermal Unit 14,501BTU/Hr 18,834BTU/Hr 25,590BTU/Hr 27,978BTU/Hr 32,414BTU/Hr 51,180BTU/Hr
Ton of Refrigeration 1.2Tons 1.5Tons 2.1Tons 2.3Tons 2.7Tons 4.2Tons
Pump Voltage/Power 220V/550W 220V/750W 220V/750W , 380V/750W 380V/750W 380V/1100W
Max.lift 40M 45M 52M 55M
Max.flow 33L/min , 2m3/h 66L/min , 4m3/h
Inlet and outlet 40mm Inner teeth 6point Inner teeth + 4point Inner teeth
Max.Capacity of Tank 19L 25L 40L 55L
Machine Dimension 700*520*1060mm 750*620*1200mm 1200*620*1200mm
NW 82KG 105KG 120KG 130KG 150KG 180KG
GW 165KG 200KG

 

Chiller JLFL-1000

Model JLFL-1000
Voltage 220V
Current 9.8A
Frequency 50Hz
Input Power 2.35KW
Rafrigeration Capacity (±3%) 4.25KW
British Thermal Unit 14,501BTU/Hr
Ton of Refrigeration 1.2Tons
Pump Voltage/Power 220V/550W
Max.lift 40M
Max.flow 33L/min , 2m3/h
Inlet and outlet 40mm Inner teeth
Max.Capacity of Tank 19L
Machine Dimension 700*520*1060mm
NW 82KG

 

Chiller JLFL-1500

Model JLFL-1500
Voltage 220V
Current 13.5A
Frequency 50Hz
Input Power 2.625KW
Rafrigeration Capacity (±3%) 5.52KW
British Thermal Unit 18,834BTU/Hr
Ton of Refrigeration 1.5Tons
Pump Voltage/Power 220V/750W
Max.lift 45M
Max.flow 33L/min , 2m3/h
Inlet and outlet 40mm Inner teeth
Max.Capacity of Tank 19L
Machine Dimension 700*520*1060mm
NW 105KG

 

Chiller JLFL-2000

Model JLFL-2000
Voltage 220V
Current 15A
Frequency 50Hz
Input Power 2.825KW
Rafrigeration Capacity (±3%) 7.5KW
British Thermal Unit 25,590BTU/Hr
Ton of Refrigeration 2.1Tons
Pump Voltage/Power 220V/750W
Max.lift 45M
Max.flow 33L/min , 2m3/h
Inlet and outlet 40mm Inner teeth
Max.Capacity of Tank 19L
Machine Dimension 700*520*1060mm
NW 120KG

 

Chiller JLFL-3000

Model JLFL-3000
Voltage 220V/380V
Current 11.5A
Frequency 50Hz
Input Power 4.29KW
Rafrigeration Capacity (±3%) 8.2KW
British Thermal Unit 27,978BTU/Hr
Ton of Refrigeration 2.3Tons
Pump Voltage/Power 220V/750W , 380V/750W
Max.lift 52M
Max.flow 33L/min , 2m3/h
Inlet and outlet 40mm Inner teeth
Max.Capacity of Tank 25L
Machine Dimension 700*520*1060mm
NW 130KG

 

Chiller JLFL-4000

Model JLFL-4000
Voltage 380V
Current 12.5A
Frequency 50Hz
Input Power 4.68KW
Rafrigeration Capacity (±3%) 9.5KW
British Thermal Unit 32,414BTU/Hr
Ton of Refrigeration 2.7Tons
Pump Voltage/Power 380V/750W
Max.lift 52M
Max.flow 66L/min , 4m3/h
Inlet and outlet 6point Inner teeth + 4point Inner teeth
Max.Capacity of Tank 40L
Machine Dimension 750*620*1200mm
NW 150KG
GW 165KG

 

Chiller JLFL-6000

Model JLFL-6000
Voltage 380V
Current 15.5A
Frequency 50Hz
Input Power 5.85KW
Rafrigeration Capacity (±3%) 15KW
British Thermal Unit 51,180BTU/Hr
Ton of Refrigeration 4.2Tons
Pump Voltage/Power 380V/1100W
Max.lift 55M
Max.flow 66L/min , 4m3/h
Inlet and outlet 6point Inner teeth + 4point Inner teeth
Max.Capacity of Tank 55L
Machine Dimension 1200*620*1200mm
NW 180KG
GW 200KG

 


Chiller Water Cooling – Model HP

Chiller HP – All

Model 15HP 25HP 40HP
Voltage 380V
Frequency 50Hz
Rafrigeration Capacity (±3%) 11.2KW 18.75KW 29.8KW
British Thermal Unit 38,214BTU/Hr 63,975BTU/Hr 101,677BTU/Hr
Ton of Refrigeration 3.2Tons 5.3Tons 8.4Tons

 

Chiller 25HP

Model Chiller Water Cooling 25HP
Refrigeration capacity 18.75 KW
British thermal unit 63,975BTU/Hr
Ton of Refrigeration 5.3 Tons
Voltage 5N-380V
Frequency 50HZ
Control mode Total power
Expansion valve 22.75 A
Vortex type Fully enclosed vortex type
Fan external rotor Axial flow fan
Fan power 1.8 KW
Fan air volume 25000 m3/h
Water pump type Pipeline pump
Water pump power 3.75 KW
Water pump head 18 M
Water pump flow Rate 800 L/MIN
Condenser type Aluminium finned copper tube
Condenser cooling air volume 25000 m3/h
Evaporator type coil
Evaporator water content 12.34 m3/h
Evaporator water solubility 0.32 m3
Water tank material SUS304
Water tank volume 300 L
Cold water outlet DN80 (in accordance with customer's)
Cold water media inlet DN80 (in accordance with customer's)
Drainpipe PVC DN25 (based on the customer's(Application)
Water spill DN20 (in accordance with customer requirements)
Water inlet DN15 (as requested by the customer)
Microcomputer controller Show status, push-button display, exert oneself 30A5000A
Inductor selection Relay output
Temperature control Range +5~+35 °C , accuracy ± 2.0 °C
Outer dimensions (Length x Width x Height) 2370 x 1120 x 1950 mm
Whole weight 790 KG

Catalog

Catalog Chiller All models (English) 👉chick here


Catalog Chiller Model JL (English) 👉chick here

Catalog Chiller JL-3000 (English) 👉chick here

Catalog Chiller JL-5000/5200 (English) 👉chick here

Catalog Chiller JL-6000 (English) 👉chick here


Catalog Chiller Model JLFL (English) 👉chick here

Catalog Chiller JLFL-1000 (English) 👉chick here

Catalog Chiller JLFL-1500 (English) 👉chick here

Catalog Chiller JLFL-2000 (English) 👉chick here

Catalog Chiller JLFL-3000 (English) 👉chick here

Catalog Chiller JLFL-4000 (English) 👉chick here

Catalog Chiller JLFL-6000 (English) 👉chick here


Catalog Chiller Model HP (English) 👉chick here

Catalog Chiller 25HP (English) 👉chick here


Manuals

downloadUser Manual Chiller JL-6000  Click here

 

Features :

  1. Dual digital tube display, set the temperature and real-time temperature at a glance.
  2. Full power refrigeration, micro-cooling, heating control (plus configuration), suitable for various working conditions.
  3. Intelligent and constant working mode, suitable for various ambient temperatures.
  4. High precision temperature control, volatility can be controlled within 0.5 °C.
  5. With temperature overtemperature alarm, sensor fault self-diagnosis function.
  6. Have the compressor over the load protection, water flow alarm function.
  7. It has anti-freeze function and can better protect machine waterway components in the low temperature environment in the North.

feature :

  1. Digital display, can quickly set the temperature and real-time temperature.
  2. Full cooling, with heat control cooling, suitable for various working conditions.
  3. Intelligent and constant working mode suitable for different temperatures
  4. High precision temperature control, fluctuation can be controlled within 0.5 °C.
  5. If the temperature is abnormal, the sensor will self-diagnose the fault.
  6. More compressors than load, water flow alarm function
  7. It has anti-freeze function and can protect the components of the water machine in low temperature environment.

Maintenance matters :

  1. Weekly or HALF-MONTHLY cleaning of dust screen or filter dirt intake, in order to avoid causing high temperature alarm of water chillers and other malfunctions.
  2. Regularly disassemble the side panels of the machine and clean the dust and dirt attached to the condenser (radiator) with a high-pressure air gun.
  3. Replace the circulating water every two months and remove and clean the filters installed so as not to cause dirty water blockage and water flow alarm.
  4. Regular inspection of water joint pipe leakage, electrical wiring fixing screw loosening, to prevent poor circuit contact.
  5. Every 15-30 days, the filters need to be cleaned to clean and dust.

Maintenance :

  1. Clean the dust screen or dirt filter every 14 days to avoid high temperature of the cooling tank and other internal devices.
  2. Regularly remove the side panel of the machine and clean the dust and dirt stuck to the condenser (radiator) with a high-pressure air gun.
  3. Change the circulating water every 2 months. Change and clean the installed filter to prevent clogging of dirty water and prevent the tank flow warning signal.
  4. Regularly check the water pipe for leaks. Loosen the screws holding the wires to prevent bad contact with the circuit.
  5. Every 15-30 days, the filter must be removed for cleaning and dust removal.

Temperature controller :

Alarm display

Fault code

Fault name

E01

Water temperature sensor failure

E02

Over high water temperature
E03

Compressor pressure failure

E04

Phase sequence error

E05

The flow of water is not smooth

E06

Water level alarm

E07

Compressor overload

E08

Over low water temperature

E09

Room temperature sensor failure

Temperature controller :

Warning signs

Error code

Error

E01

Water temperature sensor failure

E02

The water temperature is too high.
E03

Compressor pressure failure

E04

Phase sequence error
E05

The water flow is not smooth.

E06

Water level alarm
E07

Compressor overload

E08

Water temperature is lower than normal
E09

Room temperature sensor failure

Matters needing attention :

  1. The equipment must be far away from fire source, heating body and electronic components with strong interference electromagnetic wave.
  2. Equipment is prohibited from carrying liquid transportation, so as not to damage internal components.
  3. The inlet and outlet of equipment should be more than 50cm away from obstacles, so as to avoid high temperature alarm failure.
  4. The equipment should not be inverted or inclined to more than 45 degrees, so as not to damage parts.
  5. The equipment must be placed horizontally, and the lock wheel must be well fixed.
  6. It is forbidden to start the machine without water, so as not to damage internal components.
  7. The length of the external waterway should not be too long, so as not to alarm the malfunction of the waterway, specifically refer to the pump head flow requirements.

Matters of interest :

  1. The device must be kept away from fire sources, heaters and electronic components that generate strong electromagnetic interference.
  2. Always drain water from the unit before transport to avoid damaging internal components.
  3. The inlet and outlet of the equipment should be more than 50cm away from obstacles to avoid failure of high temperature alarm.
  4. The machine should not be turned upside down or tilted more than 45 degrees to avoid damaging the parts.
  5. The equipment must be placed horizontally and the wheels must be locked to keep the machine in place.
  6. Do not turn on the device while there is no water to avoid damaging the internal components.
  7. The length of the external water passage should not be too long, so as not to cause abnormal water passage (refer to the pump head flow requirements).

Prompt Message :

  1. Capacity of water tank: 12L
  2. First adds water to it, then connects the water pipe, so as to remove the internal air and prevent the self-protection of the pump.
  3. The circulating water should be distilled water and purified water.
  4. When the water level is too low, the machine must be supplemented.
  5. Under extremely cold temperatures, a volume ratio of less than 20% ethanol or non corrosive antifreeze should be appropriately added.
  6. It is forbidden to add antifreeze fluid, water tank, and corrosive liquid to copper and stainless steel.

Notification message :

  1. Water tank capacity (Capacity of water tank): 12L
  2. First fill it with water and then connect the water pipe to remove the air inside and prevent the pump from protecting itself.
  3. Circulating water should be distilled water and purified water.
  4. When the water level is too low, add more water immediately.
  5. Under cold temperatures, the volume ratio of ethanol less than 20% or a suitable non-corrosive antifreeze should be added.
  6. Do not add antifreeze, water tank antifreeze, or corrosive liquids to copper and stainless steel.

How to set the Chiller temperature JL-6000 :

1.Before setting up, the machine is in the compressor state and the pump is running. (Is the set old temperature)

  1. Press the setting button > adjust the temperature as desired, with ↑ increases the temperature value and ↓ decreases the temperature value > setting button again.
  2. The temperature will gradually adjust down when the set temperature is reached. The machine will notify the status of the increase in the Bypass valve and Compressor stops working.

How to set the machine temperature Chiller JL-6000 :

  1. Before setting, the machine is in Compressor and Pump working state (the old set temperature).
  2. Give a button Set up > Adjust the temperature as desired by increasing the temperature and decreasing the temperature > Press the button. Set up   Once again
  3. The temperature will gradually decrease. When the set temperature is reached, the machine will indicate the Bypass valve status and the Compressor will stop working.

 

Temperature adjustment procedure for Chiller model CW/JL6000

 

Stock

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Please log in to access this page.

Scroll to Top